Rosemount Pressure Transmitter 2090
Product Detailed
Related Categories:Uninterrupted Power Supply (UPS)
Detailed Product Description
1-inch flush mount compatible with a PMC®
process connection, or 11/2-inch threaded
mounting connection
Absolute or gage pressure ranges
from 01.5 to 0300 psi
20:1 turndown
Communicates via the HART® protocol
0.20% reference accuracy, including linearity,
hysteresis, and repeatability;
1-in. flush mount compatible with PMC process
connection, or 1 1/2-in. threaded mounting
connection
The 2090P has process connections that position the
isolation diaphragm flush with vessel or pipe walls,
eliminating clogging problems associated with highly
viscous processes that tend to crystallize,
polymerize, or precipitate, such as those in the pulp
and paper industry.
Absolute or gauge pressure ranges from 0-1.5 to
0-300 psi and 20:1 turndown
Higher turndown allows for lower inventories by
allowing you to measure pressures from 1.5 psi to
300 psi with only three transmitter ranges.
Communicates via the HART® protocol
The 2090P utilizes the advantages of HART
communication, enabling quick and easy reranging,
calibration and troubleshooting.
0.20% Reference Accuracy, including linearity,
hysteresis, and repeatability
The single-filled sensor system of the 2090P leads to
outstanding accuracy due to full sensor
compensation.
Functional Specifications
Service
Liquid, gas, vapor, and high-viscosity applications
Ranges
Output
420 mA dc/Digital HART Protocol
Rangedown
20:1
Load Limitations
Reverse polarity protection is standard. Maximum loop resistance
is determined by the power supply voltage as described by the
following equation:
Zero Elevation and Suppression
Zero can be suppressed between atmosphere (2090PG), or 0 psia
(2090PA) and upper range limit, provided the calibrated span is
equal to or greater than the minimum span, and the upper range
value does not exceed the upper range limit. No vacuum
calibrations are allowed on the 2090P.
Overpressure Limits
Range 1: 120 psig
Range 2: 300 psig
Range 3: 1,600 psig
Temperature Limits
Process: Codes A & C: 40 to 250 °F (40 to 121 °C)
Codes D & G: 4 to 250 °F (20 °C to 121 °C)
Ambient: All Codes: 4 to 185 °F (20 to 85 °C)
Storage: All Codes: 50 to 185 °F (46 to 85 °C)
Process temperatures above 185 °F (85 °C) require derating the
ambient limits by a 1.5:1 ratio.
Humidity Limits
0100% relative humidity
Volumetric Displacement
Less than 0.00042 cm3
Turn-on Time
2.0 seconds, no warm-up required
Failure Alarm
If self-diagnostics detect a sensor or microprocessor failure, the
analog signal is driven either high or low to alert the user. High or
low failure mode is user-selectable with a jumper on the
transmitter. The values to which the transmitter drives its output in
failure mode depend on whether it is factory-configured to
standard or NAMUR-compliant operation. The values for each are
as follows:
Standard Operation
Linear Output: 3.9 ≤ I ≤ 20.8
Fail High: I≥ 21.75 mA
Low: I ≤ 3.75 mA
NAMUR-Compliant Operation
Linear Output: 3.8 ≤ I ≤ 20.5
Fail High: I ≥ 22.5 mA
Low: I ≤ 3.6 mA
Transmitter Security
Activating the transmitter security function prevents changes to the
transmitter configuration, including local zero and span
adjustments. Security is activated by an internal jumper.
Performance Specifications
(Zero-based spans, reference conditions, and 316 SST isolating
diaphragm.)
Reference Accuracy
±0.20% of calibrated span. Includes combined effects of linearity,
hysteresis, and repeatability.
Ambient Temperature Effect per 100 °F (56 °C)
±(0.3% URL + 0.3% of span) from 40 to 185 °F (40 to 85 °C)
Stability
±0.10% of upper range limit for 12 months
Time Response
Less than 200 ms time constant (63.2% response to a step
change in pressure).
Vibration Effect
Less than ±0.1% of upper range limit when subjected to vibration
of peak to peak constant displacement of 4 mm (515 Hz) and
constant acceleration of 2 g (15150 Hz) and 1 g (1502000 Hz).
Power Supply Effect
Less than 0.01% of calibrated span per volt
Mounting Position Effect
Zero shift of up to 1.2 inH2O (0.003 bar), which can be calibrated
out. No span effect.
RFI Effect
Less than ±0.25% of upper range limit from 201000 MHz at 30
V/m with leads in conduit. Less than ±0.25% of upper range limit
from 20-1000 MHz at 10 V/m with unshielded twisted pair (no
conduit).
Physical Specifications
Electrical Connection
1/214 NPT, M20 1.5 (CM20), or PG 13.5 conduit entry
Process Wetted Parts
Isolating Diaphragm
316L stainless steel
Process Connector
316L stainless steel
Process Connection Size
11/2 11.5 NPT or 1-in. Flush Mount
Process Connector Gasket (11/2-in.)
TFE
Process Connection O-rings (1-in.)
Standard: Viton®. Optional: Buna-N or Ethylene propylene
Non-wetted Parts
Electronics Housing
Low-copper aluminum, NEMA 4X, IP65, IP67, CSA enclosure
Type 4X
Paint
Polyurethane
Cover O-rings
Buna-N
Fill Fluid
Silicone oil
Weight
Approximately 2.96 lb (1.34 kg);
Approved Manufacturing Locations
Rosemount Inc. Chanhassen, Minnesota, USA
Emerson Process Management GmbH & Co. Wessling,
Germany
Emerson Process Management Asia Pacific
Private Limited Singapore
Beijing Rosemount Far East Instrument Co., LTD Beijing, China
European Union Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found on the Rosemount website
at rosemount.com. A hard copy may be obtained by
contacting our local sales office.
ATEX Directive (94/9/EC)
Emerson Process Management complies with the ATEX
Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
2088/2090 Pressure Transmitters
Sound Engineering Practice
Electro Magnetic Compatibility (EMC) (89/336/EEC)
All 2088/2090 Smart Pressure Transmitter:
EN 61326-1:1997 with Amendments A1, A2, and A3
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical,
and fire protection requirements by FM, a nationally recognized
testing laboratory (NRTL) as accredited by the Federal
Occupational Safety and Health Administration (OSHA).
Hazardous Locations Certifications
North American Certifications
Factory Mutual (FM) Approvals
E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D.
Dust-Ignition-Proof for Class II, Division 1, Groups E, F, G,
Class III, Division 1, indoor and outdoor (NEMA 4X)
hazardous locations; factory sealed.
I5 Intrinsically safe for use in Class I, Division 1, Groups A, B,
C, D; Class II, Division 1, Groups E, F, and G; and Class III,
Division 1 when connected in accordance with Rosemount
drawing 02088-1018. Non-incendive for Class I, Division 2,
Groups A, B, C, and D.
For input parameters see control drawing 02088-1018.