Rosemount Pressure Transmitter 2088 (Absolute and Gage)

Rosemount Pressure Transmitter 2088 (Absolute and Gage)
Product Detailed

Detailed Product Description





Performance Specifications
(Zero-based spans, reference conditions, silicone oil fill, and 316L
SST isolating diaphragm.)
Reference Accuracy
±0.10% of calibrated span. Includes combined effects of
linearity, hysteresis, and repeatability
±0.075% of calibrated span (high accuracy option)
Ambient Temperature Effect
Expressed as a total effect per 50 °F (28 °C)
Total effect includes zero and span effects.
± (0.15% URL + 0.15% of span) from 40 °F to 185 °F
(-40 °C to 85 °C)
Stability
±0.10% of URL for 12 months
Vibration Effect
Less than ±0.1% of URL when subjected to vibration of: peak to
peak constant displacement of 4 mm (515 Hz) and constant
acceleration of 2 g (15150 Hz) and 1 g (1502000 Hz).
Power Supply Effect
Less than 0.01% of calibrated span per volt
Mounting Position Effect
Zero shift of up to 1.2 inH2O (0.30 kPa), which can be calibrated
out. No span effect.
RFI Effect
Less than ±0.25% of upper range limit from
201000 MHz at 30 V/m with leads in conduit. Less than ±0.25%
of upper range limit from 20-1000 MHz at 10 V/m with unshielded
twisted pair (no conduit).
Transient Protection Limits
IEEE 587 Category B
6 kV Crest (1.2  50 s)
3 kA Crest (8  20 s)
6 kV Crest (0.5 s by 100 kHz)
IEEE 472
SWC 2.5 kV Crest,1 MHz waveform
General Specifications
Tested to IEC 801-3
Functional Specifications
Service
Liquid, gas, and vapor applications
Ranges
Output
Code S: 420 mA dc
Code N: 1-5 volt dc, low power
(Outputs are directly proportional to the input pressure)
Rangedown
20 to 1
Load Limitations
Reverse polarity protection is standard. Maximum loop resistance
is determined by the power supply voltage as described by the
following equations:
Max. Loop Resistance = 43.5 (Power Supply Voltage 10.5)
Power Supply
External power supply required. Transmitter operates on
10.536 V dc with no load (612V for Low Power). Reverse
polarity protection is standard.
Current Draw
Output Code N: ≤ 3 mA without LCD display.
Overpressure Limits
Range 1: 120 psig max
All other ranges: two times the URL
Burst Pressure
11,000 psi for all ranges
Zero can be suppressed between atmosphere for gage
transmitters or 0 psia for absolute transmitters and upper range
limit, provided the calibrated span is equal to or greater than the
minimum span, and the upper range value does not exceed the
upper range limit.
Time Response
Time Constant: 200 milliseconds
Dead time: < 0.1 s
Update rate: 20 times per second minimum
Temperature Limits
Process
Silicone fill sensor: 40 to 250 °F (40 to 121 °C)
Inert fill sensor: 22 to 250 °F (30 to 121 °C)
Process temperatures above 185 °F (85 °C) require derating
the ambient limits by a 1.5:1 ratio:
Ambient:
Storage:
50 to 230 °F (46 to 110 °C)
40 to 185 °F (40 to 85 °C) with LCD display
Humidity Limits
0100% relative humidity
Volumetric Displacement
Less than 0.00042 cm3
Turn-on Time
2.0 seconds, no warm-up required
Transmitter Security
Activating the transmitter security function prevents changes to the
transmitter configuration, including local zero and span
adjustments. Security is activated by an internal switch.
Failure Mode
If self-diagnostics detect a sensor or microprocessor failure, the
analog signal is driven either high or low to alert the user. High or
low failure mode is user-selectable with a jumper on the
transmitter. The values to which the transmitter drives its output in
failure mode depend on whether it is factory-configured to
standard or NAMUR-compliant operation. The values for each are
as follows:
Physical Specifications
Electrical Connection
1/214 NPT, M20  1.5 (CM20), PG 13.5, or
G 1/2 female (PF 1/2 female) conduit entry
Process Connection
1/214 NPT female, DIN 16288 G 1/2 male, RC 1/2 female (PT 1/2
female), M20  1.5 (CM20) male
Process Wetted Parts
Isolating Diaphragm
316L stainless steel or Hastelloy C-276
Process Connector
316L stainless steel CF-3M (Cast version of 316L SST,
material per ASTM_A743) or Hastelloy C-276
Non-wetted Parts
Electronics Housing
Low-copper aluminum, NEMA 4X, IP65, IP67,CSA enclosure
Type 4X
Paint
Polyurethane
Cover O-rings
Buna-N
Fill Fluid
Silicone or inert fill
Weight
Output Code S and N: Approximately 2.44 lb (1.11 kg)
Tagging
The transmitter is tagged, at no charge, in accordance with
customer requirements. All tags are stainless steel. The standard
tag is permanently attached to the transmitter. Tag character
height is 1/8 in. (0.318 cm). A wired tag is available upon request.
Accessory Block and Bleed Valve (S5 Option)
The Rosemount 306 Integral Manifold is pre-assembled to
transmitter and leak checked.
Approved Manufacturing Locations
Rosemount Inc. Chanhassen, Minnesota, USA
Emerson Process Management GmbH & Co. Wessling,
Germany
Emerson Process Management Asia Pacific
Private Limited Singapore
Beijing Rosemount Far East Instrument Co., LTD Beijing, China
European Union Directive Information
The EC declaration of conformity for all applicable European
directives for this product can be found at rosemount.com. A
hard copy may be obtained by contacting our local sales office.
ATEX Directive (94/9/EC)
Emerson Process Management complies with the ATEX
Directive.
European Pressure Equipment Directive (PED) (97/23/EC)
2088/2090 Pressure Transmitters
Sound Engineering Practice
Electro Magnetic Compatibility (EMC) (2004/108/EC)
All 2088/2090 Smart Pressure Transmitter:
EN 61326-1:1997 with Amendments A1, A2, and A3
Hazardous Locations Certifications
North American Certifications
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested
to determine that the design meets basic electrical,
mechanical, and fire protection requirements by FM, a
nationally recognized testing laboratory (NRTL) as
accredited by the Federal Occupational Safety and Health
Administration (OSHA).



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.